Press to enter parameter menus, switch between configuration fields, and save modified settings.
Adjusting internal PID values determines how aggressively the system applies power to prevent hunting and thermal oscillations. Parameter Code Description Range / Setting Options Functional Impact Proportional Band to Full Scale Range
The controller has four front-panel keys: , Left Arrow (Shift) , Down Arrow , and Up Arrow . PV (Upper Display): Measured Value (actual temperature). SV (Lower Display): Set Value (target temperature). Changing SV:
The front faceplate contains two independent, high-visibility digital display rows alongside four physical control keys. xta-7000 temperature controller manual
Determines proportional gain response. Setting this value directly to . I Integral Time
For exact wiring diagrams and a deep dive into parameter configuration, always refer to the physical paper manual included with your unit. If you have misplaced it, you can typically search for the manufacturer's PDF by using the exact brand label located on the side casing of your specific device.
Press the Hidden Function Key briefly to toggle through parameters like input selection and output types. 4. Programming and PID Tuning Press to enter parameter menus, switch between configuration
Adjusts the proportional control band width (0 = ON/OFF mode). 30 Integral Time Adjusts integration time in seconds (eliminates offset). 240 d Derivative Time Adjusts derivative time in seconds (anticipates changes). 60 Ct Control Cycle Cycle time in seconds. Use 2-5s for SSR, 15-20s for Relays. 20 Hy Hysteresis Deadband for ON/OFF control mode (only when P = 0). 2.0 AL1 Alarm 1 Value Sets the threshold temperature for the primary alarm relay. 50.0 Sc Sensor Calibration Offsets error variations caused by long sensor lead wires. 0.0 Loc Parameter Lock
XTA-7000 Temperature Controller Manual: Comprehensive Guide and Operation Go to product viewer dialog for this item.
For more in-depth technical specifications and diagrams, you can download the full XTA-7000 Manual from the ManualLib resource. PV (Upper Display): Measured Value (actual temperature)
Disclaimer: Always refer to your specific XTA-7000 manual for your exact model revision, as wiring and menu structures may vary slightly.
Bring your system close to its normal operating environment. Press and hold the button to enter the parameters menu. Scroll until you see the parameter labeled AT . Change the value from 0 (Off) to 1 (On). Press SET to exit the menu.
Use the and Down (▼) keys to adjust the target temperature value. Press SET again to save and return to the normal display. Advanced Parameter Access