Note: The module is powered from the input side, so input voltage must be present for the unit to operate.
If you're looking for additional resources or support, here are some options:
Short press the DOWN button to turn the relay off immediately.
features two distinct operational states. You must wire the module explicitly based on your specific application. 1. Charging Control Mode (P-1 / "IN") xycd60 manual
Long press the SET button for approximately 5 seconds to save your values and return to the main interface. Working Modes
Реле заряда-разряда аккумулятора XY-CD60L
I can provide the specific UP and dn parameters for your setup. Share public link Note: The module is powered from the input
The is a dual-mode DC voltage controller (6V–60V) designed for automated battery charging and discharge protection. It is commonly used as a voltage-sensitive relay to prevent overcharging or deep discharge in 12V, 24V, and 48V systems. 1. Setup and Quick Guide
Long press the SET button for 5 seconds to save and exit. Parameters Defined UP (Upper Limit): High voltage threshold. dn (Lower Limit): Low voltage threshold.
A: Yes, it is highly suitable. Set dn (lower limit) to roughly 10.5V-11V and UP (upper limit) to 14.4V-14.6V for typical 12V Li-ion protection. You must wire the module explicitly based on
Yes, as long as the battery voltage is between 6 V and 60 V. However, for multi‑cell Li‑ion packs, a dedicated Battery Management System (BMS) is still required for cell‑level balancing and short‑circuit protection.
The XY-CD60 features a clean LCD layout and three simple navigation buttons: UP , DOWN , and SET .
Below is a breakdown of the core functions and setup steps typically found in the XY-CD60 manual Core Operating Modes