Skip to content

Emc 2064 Weigh Batch Controller Manual Pdf

For immediate technical support or manual requests:

High-resolution monitoring of weight change, capable of high-accuracy batching.

Unlike a simple scale indicator that just tells you how much weight is in a hopper, a is proactive. It doesn't just observe; it commands. The EMC 2064 is designed to control the flow of materials—typically aggregates, cement, water, and additives—by actuating gates, valves, and pumps.

Utilizes an advanced analog-to-digital converter to process load cell signals rapidly and accurately.

Prepare a clean panel cutout according to the mechanical specifications provided in the official manual dimensions (typically standard DIN sizes). emc 2064 weigh batch controller manual pdf

The controller is set up to receive material while the hopper is filled, regulating the slide valve or feed valve.

The 8 onboard digital relay outputs can drive external inductive loads such as pneumatic solenoids, starter relays, or digital inputs on a master PLC.

The EMC 2064 isn't limited to a single silo. It is engineered to handle multiple ingredients. It can cycle through a sequence of aggregate bins, weighing each one cumulatively into a single hopper. It stores multiple recipes, allowing an operator to switch from "Mix Design A" to "Mix Design B" with just a few button presses, without recalibrating the entire system.

Pairs with mechanical Gross Weigher setups, activating bag clamps and dual-position radial gates for fast and dribble filling. 2. Technical Specifications The EMC 2064 is designed to control the

feature that automatically compensates for product still in motion (in-flight) after the gates close. Multi-Batch Option:

Like any complex device, the EMC 2064 Weigh Batch Controller may require troubleshooting and maintenance from time to time. The following steps outline common issues and solutions:

Tracks actual negative voltage at the junction. Signal Positive (SIG+): The positive millivolt ( ) output from the strain gauge. Signal Negative (SIG-): The negative millivolt ( ) output from the strain gauge.

Can be configured to batch "into" a hopper (weight gain) or "out of" a hopper (weight loss). The controller is set up to receive material

The EMC 2064 allows you to set:

[Insert your Google Drive, Dropbox, or ManualsLib link here]

Imagine you are batching sand. You open a gate, and sand rushes into the weigh hopper. When the scale reads the exact target weight (say, 1,000 kg) and you close the gate, the sand already in the air above the hopper continues to fall. The result? You end up with 1,050 kg.

Choose between two primary configurations: